Scope: This specification defines the performance characteristics of a 12 volt 2.0A portable battery charger with float mode charging. The specification also defines world wide safety and operating requirements.

  • Input Requirements
  • Output Requirements
  • M.T.B.F.
  • Protection
  • Electromagnetic Requirements
  • Safety Requirements
  • Environment
  • Dimensions

 

 

 

 

Battery Doc Wall Mount II

INPUT REQUIREMENTS

Line Voltage (VAC)

  • 100 VAC-240VAC ± 10% /47Hz to 63 Hz input

Inrush Current

  • (a) 30A max. @ 115VAC under the worst case load and cold start
  • (b) 60A max. @ 230VAC under the worst case load and cold start

Input Current

  • 0.5 RMS Max. at full load and 115 VAC input
  • 0.25 RMS Max. at full load and 230 VAC input

Efficiency

  • 70% min. at specified line voltages, outputs at full load

Input Transient Protection

The output shall be isolated from the input and the supply shall be able to withstand without permanent damage.Power line transients as defined in IEC 801-4 or IEC 801-5, line to neutral 1 kV line to neutral with floating ground, 2kV.

OUTPUT REQUIREMENTS

Voltage
Load Current
Tolerance

Min.

Max.

Total Reg.

+13.75Vdc

0.0A

2.0A

±6%

Line Regulation

  • 1% measure at 115VAC or 230VAC±15%

Load Regulation

  • ±5% measure at all output from min. load to max. load
    at 115VAC ,60Hz.

 

M.T.B.F.

M.T.B.F. shall be a min. of 100,000 hours when operated at
25 °C ambient, running at 100% duty cycle with the following line and load conditions:

 

 

 
 

PROTECTION

Over Current Protection

  • Electronically controlled
  • Unit will sustain "No Damage" when connected with reverse battery polarity.

Short Circuit Protected

  • For any output shorted to ground, grounded output will not damage this power supply. A short to the ground will be defined as a maximum of 0.1.

Reverse Battery Protected

  • Unit will sustain "No Damage" when connected with reverse battery polarity.

 

ELECTROMAGNETIC REQUIREMENTS

The radiated and conducted emissions of this adapter comply with the requirements of United States Federeal Communication Commission (FCC) part 15, class B and with CISPR 22.and CISPR 22.

SAFETY REQUIREMENTS

  • The power supply is approved for the following:
    • UL 1236
    • CUL

HI POT TEST

  • HI POT A: Primary - Secondary (FG) - 1500VAC for 60 seconds or DC equivalent 2121VDC for 60 seconds. If DC voltage used for test, the voltage should ramp up and down with 1 sec. rise time.
  • HI POT B: Transformer Primary - Secondary - 3750VAC for 1 minute (component level).

Burn-In Test

  • 4 hours at 40 ± 5°C, Nominal input voltage, 80% of maximum load

ENVIRONMENT 

Temperature and Humidity

  • (1) Operating temp. is 0 °C to 40°C.
  • (2) Storage temp. is -20°C to 85° C.
  • (3) Operating humidity is 15% to 85% RH
  • (4) Storage humidity is 5% to 90% RH

 

DIMENSIONS & WEIGHT

  • LxWxH: 104mm x 58mm x 31.8mm
  • Weight: 240 g Typical

Contact Us   7491 Cahill Road Minneapolis, MN 55439  Phone: 800.959.0879  Fax: 952.941.0659